极品无码av国模在线观看,好男人好资源官网在线观看,精品无码久久久久久尤物,青青草原综合久久大伊人精品

CN
Home > Products > Spectrograph & Monochromator > Integrated System & Application > Detector Responsivity Measurement System

DSR100 Series

Detector Responsivity Measurement System

Inquiry
Download
Details
Detector Responsivity Measurement System

Photodetector is the sensor that could convert the optical radiation signal to the electrical signal, which is made from photoemission material. Most of the photodetectors have strong spectral selectivity in a certain Spectrum area. Therefore, for one photodetector, different wavelengths have different spectral responsivity. The spectral responsivity is an important parameter index for characterizing the photodetector performance.
And for the photoelectric material researching , the effect of some characteristics of the material itself such as doping density, lattice imperfection, absorption coefficient and minority carrier diffusion length on the photoelectric response capacity and the quantum efficiency could be obtained by measuring and analyzing the spectral responsivity data. That is very important and helpful for choosing better material and processing improvement.


DSR100 Detector Responsivity Measurement System

Application
 
■ DUV detector
■ Solar cell detector
■ Optical fiber sensor
■ IR photoelectric sensor


System Specifications
 
Model DSR100-X150A-A DSR100-T75SiN40-A
Wavelength Range 200~2500nm 350~14­m
Light source UV enhanced Xenon light source Tungsten-halogen lamp and siliconnitride light source
Repeatability*1 200~450 nm ≤ 2% -
450~1800nm ≤ 1% ≤ 1%
1.8~2.5 ­m ≤ 2.5% ≤ 1%
2~6 ­m - ≤ 3%
6~14 ­m - ≤ 5%
Optical UV enhanced Silvering
Spot ≤Φ1 mm ≤Φ1 mm
*1. Repeatability data is provided when the peak wavelength signal intensity is closing to the saturation value of the detector, and there are different standard detectors to cover the different wavelength range.

Standard Reference Detector Accessories
 
Model Wavelength Range Calibrated by
DSR-A1 200~1100 nm National Institute of Metrology, China
DSR-A7 300~1100 nm National Institute of Metrology, China
DSR-T1 350~1000 nm NIST-traceable
DSR-T2 800~1800 nm NIST-traceable
DSR-A2 800~2500 nm Xi 'an Institute of Applied Optics, China
DSR-A8 1~14 ­m Xi 'an Institute of Applied Optics, China

System Size

Sample Test

Si Detector
Wavelength range: 200-2500nm
Wavelength spacing: 10nm
Bias voltage: 1V
Chopper frequency: 330 Hz


System Benefits

◆Wide wavelength range (200~14000 nm, optional), widely applicable
◆Turnkey system, Easy maintenance.
The system uses substitution method of measuring principle, which is designed into Turnkey mode. Users do not need to debug the system before experiments. Routine maintenance is also very simple.
◆CCD monitoring optical path for sample location. The detectors with very small area can be located precisely by the system.
◆perfect reflection optical design, optimization of spot quality
the perfect reflection optical system, you can get the quality parallel spot or much small convergency spot.


◆High stability light source, reducing the background noise.

◆Data export format supports third- party software.
DSR100 can save all original data, and the experimenter can save the data as the *.txt, *. *.xls* and so on.